WIDAL Test

ebn benghazi

WIDAL Test:

Procedure:

The reagents must have the room temp. before using.
Prepare white slide for using.

Put 20 µ of the reagent A , B , O & H on the white slide separating each other by enough space then put 10 µ serum at each reagent zone

Mix each reagent with it's neighbor serum quickly begin rotate the 4 reagents together for 1 min.

The result depends on each reagent.

If -ve so result have titre 1/40.
If +ve (ppt occur) so the titre 1/80 and repeat by dilution the serum with saline by ratio 1 : 1. Put 10 µ of serum mix 1 with 20 µ of reagents that gives +ve result only by the same steps.

If -ve so result 1/80
If +ve so the titre 1/160 and repeat by the same steps of dilution.

The titre of this test is :

1/40 , 1/80 , 1/160 , 1/320 , 1/640

The diagnostic titre is 1/160 .




http://laboratorymedicne.blogspot.com/
http://visualbasicall.blogspot.com/ 
http://medicalwindows.blogspot.com/
http://www.saad6.com
Medical Editorial Information

This article is provided for educational and laboratory-medicine information. Clinical decisions should be based on the patient context, current evidence, and guidance from a qualified healthcare professional.

Author: ebn benghazi Published: 2010-06-25T16:40:00-07:00
Explore this topic

Post a Comment

Cookie Consent
This website uses cookies to analyze traffic, remember your preferences, and improve your browsing experience.
Oops!
It looks like there is a problem with your internet connection. Please check your connection and try again.
AdBlock Detected!
لقد اكتشفنا أنك تستخدم إضافة حظر الإعلانات في متصفحك.
الإيرادات التي نحصل عليها من الإعلانات تُستخدم لإدارة هذا الموقع، نطلب منك إضافة موقعنا إلى قائمة الاستثناءات في إضافة حظر الإعلانات الخاصة بك.