Acetate filter PAP stain for the urinary cytodiagnostic

Reagents

  • Filter (Gelman GN6 13 mm) or (Millipore RAW 013 )
  • Filter holder sweeny 13 mm
  • Hank's solution
  • Hématoxiline acide free
  • Orange G ( Ortho )
  • Ea 65 ou Ea 50 ( Ortho )
  • EtOH 95%, 1-propanol, toluène

Acetate filter procedure

  1. Centrifuge 10 ml of urine
  2. Decant a maximum of supernatant
  3. Resuspend the pellet to 1 ml with Hank's solution. Verify the cellularity. Dilute if necessary
  4. Bring to volume to its initial value using Hank. Mix
  5. Place the acetate filter in ethanol 95% for 10-15 sec, mount on the sweeny filter holder.
  6. Rinse the filter by injecting 2 ml of Hank
  7. Inject with a seringe, 1ml or less of the sediment suspension, depending on the cellularity.
  8. Rinse the filter by injecting 2 to 5 ml of Hank
  9. Un-mount the holder and retrieve the filter.
  10. Fix immediately with EtOH 95%. Never let the filter dry out.
  11. Stain and mount.

PAP stain for acetate filter

From: Barwick H. McGill University ( personnal communication)
  1. EtOH 95%............................10 min.
  2. H2O ....................................10 min.
  3. Hematoxiline** .....................2 min.
  4. H2O tap ..............................10 min.
  5. HCl 0.05% ..........................7 dips (destain as needed )
  6. H2O tap 37°C .....................6 min.
  7. EtOH 95% ...........................2 min.
  8. Orange G** ........................2 min.
  9. EtOH 95% ..........................2 min.
  10. EtOH 95% ..........................2 min.
  11. EtOH 95% ..........................2 min.
  12. EA 65**...............................2 min.
  13. EtOH 95%............................2 min.
  14. EtOH 95%............................2 min.
  15. EtOH 95%............................2 min.
  16. 1-propanol 100%..................2 min.
  17. 1-propanol 100%..................2 min.
  18. 1-propanol /Toluène ( 1:1).....2 min.
  19. Toluène..................................6 min.

Mount

  1. Slide
  2. 1 drop of Eukitt
  3. Put the filter on the drop
  4. 2 to 4 drops of Eukitt on the filter
  5. Add the coverslip
Put on a heating plate adjusted at 50C, and let the resin disperse.

Results

PAP stain This procedure is used for collection purpose.